R.H. Peterson G8 series Owner's Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24
IN
TH
TP
TH
TP
IN
OUT
When shutting your burner down, be sure to TURN THE
FLAME FULLY OFF (to PILOT or OFF). Make sure the
burner is completely off for one minute before relighting.
ADJUSTING THE ODS PILOT
a. The ODS pilot fl ame should encircle the generator
tip, and is preset at the factory (
Fig. 24-2).
Ordinarily, the ODS pilot will not require field
adjustment.
b. If adjustment is necessary, remove the cap screw
(
Fig. 24-1) and turn the smaller gas adjustment
screw inside
counterclockwise to increase the
ODS pilot fl ame, and
clockwise to decrease
the ODS pilot fl ame. Replace the cap screw.
MAINTENANCE
Your pan burner is equipped with a safety ODS pilot
that will shut off the gas supply in case the ODS pilot is
not burning or functioning properly. Make sure the ODS
pilot is adjusted properly and that the generator spade
clips are tightly connected to the terminal screws on
the valve. If the ODS pilot will not stay lit, call your local
gas utility or gas supplier.
A periodic check of the following should be performed
at least annually by a qualifi ed professional service
representative:
1. Valves and switch for proper operation.
2. Flue system for rust, damage, or leaks.
3. Damper operation.
4. Orifi ces for dirt or other foreign matter.
5. Visual check on the burner.
If this unit was shipped with a remote, or if a remote
system was installed later, read and follow the
separate remote instructions to operate the burner
remotely.
WARNING
If you do not follow these instructions exactly, a fi re or explosion may result, causing property
damage, personal injury, or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician
to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
FOR YOUR SAFETY, READ BEFORE LIGHTING
LIGHTING THE ODS PILOT
To read the safety valve control knob (Fig. 24-1),
read the marking nearest the teardrop-shaped metal
pointer.
1. If the safety valve control knob is in the PILOT
position, push in slightly on the knob and rotate it
clockwise
to the OFF position.
2. Release knob and wait fi ve minutes.
3. Turn safety valve knob counterclockwise to the
PILOT position. (Only the ODS pilot gas will fl ow
when the knob is pushed in.)
4. Place a long match or a butane lighter at the ODS
pilot burner, and at the same time, push the safety
valve knob fully in. The ODS pilot will light.
5. Hold the safety valve knob in for approximately 60
seconds before releasing.
6. If the ODS pilot does not stay lit, turn the safety
valve knob clockwise
to the full OFF position.
Wait fi ve minutes, then repeat steps 3 through 5.
IGNITING THE MAIN BURNER
With the ODS pilot lit, turn the safety valve knob
counterclockwise to the ON position. Flip the switch
control to the ON position and the burner will light.
Refer
to the PARTS LIST for the switch location.
SHUTTING OFF THE MAIN BURNER
Flip the switch control clockwise to the OFF position.
The ODS pilot will remain lit.
SHUTTING OFF THE ODS PILOT
Be sure the switch control is OFF and depress and turn
the safety valve knob
clockwise to the OFF position.
Fig. 24-1
Wiring harness
ODS pilot
cap screw
HI/LO fl ame
height knob
Note: ODS pilot fl ame should encircle top of the thermopile
Fig. 24-2 Lighting the ODS pilot
LIGHTING INSTRUCTIONS - SERIES 12 VALVE
The Real-Fyre
®
burner system has an ODS (Oxygen Depletion Sensor) pilot which can be lit by hand using a match or lighter.
When lighting the ODS pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the fl oor as some gas is heavier than
air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't
try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.
Flame touching
Thermocouple
ODS pilot
gas port
Safety
valve
control
knob
To remote
(if applicable)
Switch
The Real-Fyre
®
burner system has an ODS (Oxygen Depletion Sensor) pilot that can be lit by using the built in piezo ignitor switch
on the burner, or by hand using a match or long necked lighter. When lighting the ODS pilot, follow these instructions exactly.
4. Push and hold the safety valve knob fully in and
push in the piezo ignitor button several times until
the ODS pilot lights.
Page view 23