1
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
INSTALLATION &
OWNER’S MANUAL
WARNING: If the information in this manual
is not followed exactly, a fi re or explosion may
result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
- A propane cylinder not connected for use
shall not be stored in the vicinity of this or
any other appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open fl ame.
3. If odor continues, keep away from the
appliance and immediately call your gas
supplier or fi re department.
Installation and service must be performed by
an NFI Certifi ed or other qualifi ed professional
installer, service agency, or gas supplier.
F14-023
WARNING
Improper installation, adjustment, alteration,
service, or maintenance can cause property
damage, personal injury, or loss of life. Read
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
CODE AND SUPPLY REQUIREMENTS:
The gas installation must conform with local codes
and ordinances, or, in the absence of local codes,
with the latest National Fuel Gas Code, ANSI Z223.1.
The R.H.P. gas appliance is designed as an
attended appliance. Adults must be present when
the unit is operating. DO NOT leave the unit burning
when unattended. If the product is left burning
unattended, it may cause damage or serious injury.
INSTALLER & CONSUMER: These instructions MUST
be retained with this unit for future reference.
Important: Read these instructions carefully
before starting installation of the unit.
IMPORTANT
For safe operation and proper performance of
this product and to comply with certification,
listings, and building code acceptances, use ONLY
Robert H. Peterson (R.H.P.) controls, parts, and
accessories that have been specifi cally listed or
certifi ed for use with this fi replace. Use of other
controls, parts, or accessories is prohibited and
will void all warranties, certifi cations, listings, and
building code approvals, and may cause property
damage, personal injury, and loss of life.
Complies with:
ANSI Z21.97/CSA 2.41 for
outdoor decorative gas
appliances
(when installed with select
R.H.P. Vented/Unvented
Gas Appliances)
WARNING: For Outdoor Use Only
DANGER
CARBON MONOXIDE HAZARD
A vented gas appliance can produce
carbon monoxide which has no odor.
Using it in an enclosed space can
kill you.
Never use the appliance in an
enclosed space such as a camper,
tent, car, or home.
REV 1 - 1411101150
L-H2-010
CORDOVA (STANDARD, REDUCED, GRAND) OUTDOOR FIREPLACES
Vented Series: 022, 023, 882
Unvented Series: 122, 123,182
022
series
shown
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1 - OWNER’S MANUAL

1Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Indus

Page 2 - MODE D'EMPLOI

10SPECIFICATIONS AND DIMENSIONS (cont.)Hearth Style Dimensions * 16" Rectangle Bullnose Hearth 76" w x 41" d x 16" h 4" R

Page 3 - TABLE OF CONTENTS

11SPECIFICATIONS AND DIMENSIONS (cont.)This fi replace is designed to be installed with an R.H.P. vented/unvented gas appliance. Below is a list of the

Page 4

12The dimensions shown below are MINIMUM CLEARANCES to maintain when you install the unit.ALL CLEARANCES AND INFORMATION STATED HERE MUST BE MAINTAINE

Page 5

13PARTS LISTIMPORTANT Remove all packing material (including any protective coatings) and discard prior to use.• Your fi replace is packaged onto 1 pa

Page 6 - OPÉRATION DE COUPLEUR RAPIDE

14PARTS LIST (cont.)IDENTIFICATION PARTS LISTGrand Cordova (882, 182)12431156Item Description Qty.1.ororHearth assembly - 110" Rectangle Extended

Page 7 - QUICK COUPLER OPERATION

15IMPORTANT SAFETY INFORMATIONBE CAREFULIf not installed and used correctly per these instructions, this product can cause serious injury.CAUTION: In

Page 8 - NOTES PAGE

16FIREPLACE INSTALLATION (cont.)FIREPLACE ASSEMBLY - OVERVIEWCAUTION: Fireplace components are heavy. CAREFULLY handle all components during assembly

Page 9 - SPECIFICATIONS AND DIMENSIONS

17FIREPLACE INSTALLATION (cont.)FIREPLACE ASSEMBLY - STEP BY STEPCAUTION: Fireplace components are heavy. CAREFULLY handle all components during asse

Page 10 - Table 2 - Hearth Dimensions

18FIREPLACE INSTALLATION (cont.)Middle Body1. Place the middle body piece on top of the base body piece. Carefully align the pilot holes, and repeat

Page 11 - (Log Set or Glass Models)

19FIREPLACE INSTALLATION (cont.)Liners, Top Body, & Chimney1. Install the fi rebox liners into the interior of the fi rebox in the order shown in F

Page 12

2 AVERTISSEMENTL'installation, l'ajustement, le changement, le service, ou l'entretien inexact peuvent causer des dégats mat

Page 13 - PARTS LIST

20BURNER INSTALLATIONBURNER INSTALLATION GUIDELINESThis fi replace is designed to be installed with an R.H.P. vented/unvented gas appliance. The gas ap

Page 14 - PARTS LIST (cont.)

21OPTIONAL ACCESSORIESOPTIONAL GFRC CHIMNEY RAIN VENT CAPAn optional GFRC chimney rain vent cap is available to protect your unit from the rain. Conta

Page 15 - FIREPLACE INSTALLATION

22AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S'ENSUIVRE, CAUSANT DES DOMMAGES MAT

Page 16 - ASSEMBLY / INSTALL OVERVIEW

23TO LIGHT THE APPLIANCE1. STOP! Read the safety information above.2. Follow the lighting instructions found in the owner's manual provided with

Page 17 - Connect Gas Supply

24SERVICING AND CLEANINGEach installation site for any unit presents its own unique combustion environment. Specifi c factors such as weather, wind cu

Page 18 - Middle Body

25SERVICING AND CLEANING (cont.)If you have trouble with your gas appliance, please refer to the owner's manual provided with it. By trying one o

Page 19 - Grout Seams

26Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Quality Check Date:_________________Model#: ___________________Ser

Page 20 - BURNER INSTALLATION

3TABLE OF CONTENTSIMPORTANT SAFETY INFORMATIONCongratulations on your purchase of an American Fyre Designs outdoor gas fi replace. Made with pride in A

Page 21 - OPTIONAL ACCESSORIES

4PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINESThis fi replace is designed to be installed with select R.H.P. vented/unvented gas appliances. The f

Page 22

5OPERATING THE UNIT SAFELY AND CORRECTLYINSTALLATION SAFETY GUIDELINESA. Installation and repair should be done by a qualifi ed professional service t

Page 23 - LIGHTING GUIDELINES

6ULFig. 6-1 type coupleur rapide de fi l de point culminant d’IValvede décompressionQCC Type 1 ValveAjustage de précision en laiton de fi l de point cul

Page 24 - SERVICING AND CLEANING

7ULFig. 7-1 Type I Acme thread quick couplerPressure relief valveQCC Type 1 valveBrass Acme thread fi ttingLiquid level indicator (optional)Hand nut wi

Page 25 - TROUBLESHOOTING

8NOTES PAGEPlease use this page to record any information that you may want to have at hand.

Page 26 - WARRANTY

9SPECIFICATIONS AND DIMENSIONSFireplace Style Dimensions Weight / PiecesCordova Fireplace (022 & 122) * 76" w x 41" d x 95" h 1700

Comments to this Manuals

No comments