TROUBLESHOOTING (Cont.)
POSSIBLE CAUSE SOLUTIONS
A. Low gas pressure A. Check gas pressure (see Section 1, A1 of this table).
B. Drafts in room B. Eliminate drafts by closing heating and air conditioning vents,
returns, and outside air vents. Fans blowing directly into fi replace
should be turned off when system is operating.
C. Air shutter(s) blocked C. Burner air shutter(s) are blocked with debris. Vacuum debris in and
around burner area.
D. Using a product other than Real-Fyre
®
gas logs
with burner
D. Make sure only Real-Fyre
®
vent-free gas logs are used with your
vent-free burner.
E. Using natural gas burner on propane gas or
propane burner on natural gas
E. Make sure burner is set up for the gas you are using. Check
nameplate attached to burner. Call your dealer immediately if
nameplate does not match the gas you are using.
F. Adding any accessories to burner system F. Shut down burner system and take off any accessories that do not
belong with the system.
G. Blocked orifi ce(s) or air shutter(s) G. Dust, lint, fi bers, paper, spider webs, pet hair, etc. in the fi replace
and on the burner assembly can affect the operation of the burner
and the ODS pilot assembly. Clean out the debris and vacuum
around burner for dust that may have accumulated over time.
Vacuum the ODS pilot assembly and over the air shutter holes.
Any blockages in this area will affect the operation of the ODS
sensor.
H. Log placement H. Some log sets have notches on the bottom front and rear logs to
restrict any side-to-side movement. The log support/main burner
brackets restrict any forward or backward movement. Make sure
log set is placed in its proper position as instructed in the owner’s
manual, so there is no fl ame impingement on log set.
I. Too many embers on the ember burner (where
tted)
I. Remove any additional embers not included with your vent-free gas
log set. Important: DO NOT ADD ANY ADDITIONAL EMBERS
TO THIS LOG SET. ANY ADDITIONAL EMBERS MAY CAUSE
UNSAFE OPERATION.
A. Haven’t held knob in long enough A. Hold knob in for 1 minute and release. If the knob doesn’t hold,
contact your dealer for service ( valve replace or new ODS).
WHISTLING NOISE COMING FROM BURNER
A. Burner may be cold or may have not been used
for a prolonged period of time
A. Allow burner to warm up on low.
B. Air in gas line B. Contact your gas company.
C. Clogged air openings C. Clean all air openings.
POPPING NOISE COMING FROM BURNER
A. Flash tube blocked A. Clear fl ash tube of all obstructions, especially around the bottom.
SOOTING
ODS PILOT WILL NOT STAY LIT WHEN KNOB IS RELEASED
WARNING: If the gas quality is bad, the burners will produce soot and/or your pilot will not stay lit.
Contact your gas company.