SPECIFICATIONS AND REQUIREMENTS (cont.)
Any installation of this appliance is subject to minimum fi replace size requirements below:
Log Set
Size
Fireplace Size
BTU Rating
(for either natural or
propane gas)
Width Depth Height
16
"
17" front
13" rear
*
9
1
/
2
" 17"
20,000
9,500 (reduced)
20
"
21" front
13
" rear*
9
1
/
2
" 17"
20,000
9,500 (reduced)
24
"
26" front
13
" rear*
9
1
/
2
" 17"
20,000
9,500 (reduced)
* based on minimum depth
Minimum Permanent Chimney Vent Opening
(when used as a vented appliance)
Standard Models
Table 4-2
Chimney Height
Factory built
replaces
Masonry built
replaces
15' 9 sq. in. 14 sq. in.
20' 8 sq. in. 13 sq. in.
25' 7 sq. in. -
30' 6 sq. in. 12 sq. in.
Minimum Permanent Chimney Vent Opening
(when used as a vented appliance)
RP Models
Table 4-3
Chimney Height
Factory built
replaces
Masonry built
replaces
15' 4.5 sq. in. 7 sq. in.
20' 4 sq. in. 6.5 sq. in.
25' 3.5 sq. in. -
30' 3 sq. in. 6 sq. in.
This unit may not be installed in a vented fi replace with a chimney of less than 15 feet in height.
Observing minimum fi replace dimensions and centering the appliance in the fi replace will ensure
adequate clearance for operation and servicing. It may be necessary to uninstall the unit for
some types of service.