1Robert H. Peterson Co.ModelsG46-18/20-01(P)G46-18/20-11(P)G46-18/20-15(P)G46-18/20(P)G46-24-01(P)G46-24-11(P)G46-24-15(P)G46-24(P)G46-30-01(P)G46-30-
10CONNECTING THE IGNITION PACK TO THE G46-01(P) VALVEThe G46-01-xx(P) valve comes complete with the wiring harness connected to the pine cone switch.
11SECURING THE BURNERYour gas log set has 2 securing holes at the front of the burner pan heat shield (see parts list and Figure 8 for location). Mark
12Note: For Charred Series see Page 14 For Western Campfyre Series see Page 15.Proper log placement is important to insure proper performance of you
13INSTALLING YOUR REAL-FYRE GAS LOG SET (Continued)The illustrations below (Figures 12A-C and 12D-F for Split Oak) show the three basic log placemen
14 If you have purchased this style of log set, follow the instructions below.NOTE: The logs for the CHD Charred Oak Set are illustrated. Log style
15INSTALLING YOUR REAL-FYRE GAS LOG SET (Continued)WESTERN CAMPFYRE STYLE LOGS LAYOUT SUMMARYIf you have purchased this style of log set, follow the
161. Use "OFF" only when complete shutdown is necessary.1. STOP Read the safety information on this page.2. Turn "OFF" any ele
171. ARRETEZ! Lisez les renseignements de securite au-dessus.2. Arretez "FERMÉ" tout appareil electrique (tel le Circulateur d’Air Chaud d
18 1. STOP! Read the safety information above. 2. Turn "OFF" any electrical appliance (such as the Peterson warm air circulator or remote
191. POUR ALLUMER - Tournez le robinet jusqu’a la position “FERMÉ” et attendez 5 minutes avant d’allumer. 1. ARRETEZ! Lisez l'information de
2Votre Real-Fyre de Peterson Tronçonne l'Ensemble est est installé seul dans un solide-combustible cheminée brûlante avec un [fl ue] qui travaille
20FOR YOUR SAFETY, READ BEFORE LIGHTINGThe Real-Fyre G46 Series gas log set has a pilot which can be lit by hand using the piezo ignitor. When li
21CETTE UNITÉ (G46-01) A UN PILOTE DE LA NON-POSITION.ALLUMER LE BRÛLEUR PILOTE ET PRINCIPAL.1. ARRÊTEZ! Lisez l'information de la sécurité au-de
221. Using remote handset, turn main burner off by pressing "DOWN" button. Pilot will remain lit. 2. If complete shutdown is desired, WHEN
23POUR VOTRE SECURITE, LISEZ AVANT D’ALLUMERPRÉVENIR: Si vous ne suivez pas ces instrucions exactement, un feu ou explosion peuvent résulter, en caus
24The pilot burner is preset at the factory and normally should not require adjustment. However, if adjustment is necessary, the following steps shoul
25To adjust the fl ame pattern, take a long blade screwdriver or similar tool and stir the granules until the desired pattern is achieved. DO NOT REMOV
26FOR USE IN THE COMMONWEALTH OF MASSACHUSETTSINSTALLATION OF THIS APPLIANCE MUST BE PERFORMED BY A MASSACHUSETTS LICENSED PLUMBER OR GAS FITTER ONLY
3G46 GAS LOG SETTABLE OF CONTENTSCover - Important Safety Warnings 1-2Table of Contents 3 Burner - Parts Lists: General Burner and Log Parts Li
4PARTS LIST FOR REAL-FYRE G46 SERIES GLOWING EMBER GAS LOG SETS Log styles, sizes and parts will vary depending upon the G46 Series model ordered.
5SAFETY CONTROL SYSTEM FOR G46 MANUAL SAFETY CONTROL SYSTEM FOR G46-11(P)G46 Burner showing valve layout under heat shield.NOTE: DO NOT REMOVE HEAT S
6 SAFETY CONTROL SYSTEM FOR G46-01(P) G46 Burner showing Remote Control layout under heat shield.NOTE: DO NOT REMOVE HEAT SHIELD SAFETY CONTROL SYSTE
7G46 SERIES IMPORTANT INFORMATIONDo not use this log set if any part has been under water. Immediately call a qualifi ed professional service technicia
8DAMPER CLAMP INSTRUCTIONSThe damper clamp with hex bolt (Figure 1) is provided as a means to prevent full closure of the damper blade. The clamp is e
91. The burner gas inlet is located in front of the gas valve (Figure 3). Use tefl on tape or pipe compound on all pipe thread male connections, excep