R.H. Peterson G45-2 SEE-THRU Series Owner's Manual

Browse online or download Owner's Manual for Fireplaces R.H. Peterson G45-2 SEE-THRU Series. R.H. Peterson G45-2 SEE-THRU Series Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
REV 6 - 1305220905
L-A2-208
1
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
OWNER’S
OWNER’S
MANUAL
MANUAL
Standard Burner Systems:
G45-**(P)A
G45-**-01(M)(P)
G45-**-11(M)(P)
G45-**-15(M)(P)
G45-**-17(M)(P)
**Sizes:
(16/19, 18/20, 24, 30, 36)
For indoor stainless steel models;
add (-SS) to end of model #
The Real-Fyre gas log set is to be installed only in a
solid-fuel burning fi replace with a working fl ue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure of
the damper blade. The chimney damper MUST be
fully opened when burning the log set. The log set is
designed to burn with yellow fl ames; thus adequate
ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this log set, use ONLY Peterson
parts and accessories. Use of other controls, parts,
and accessories that are not designed for use with
Real-Fyre gas log sets is prohibited and will void all
warranties, certifi cations, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life.
*Note: Solid-fuels shall not be burned in a fi replace
where a decorative appliance is installed.
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE LOG SET
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not
followed exactly, a fi re or explosion may
result, causing property damage, personal
injury, or loss of life.
This appliance is only for use with the
type of gas indicated on the rating plate.
Installation and service must be
performed by a qualifi ed professional
installer, service agency, or the gas
supplier.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
G45 SERIES VENTED GAS LOG SETS (REGULATED)
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60-2012
CSA 2.26-2012
11-020
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - OWNER’S

REV 6 - 1305220905L-A2-2081ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746 OWNER’S OWNER’S MANUALMANUALStandard Bu

Page 2 - REV 6 - 1305220905

10Do not use this log set if any part has been underwater. Immediately call a qualifi ed professional service technician to inspect the appliance and t

Page 3 - TABLE OF CONTENTS

11The damper clamp with hex bolt (Fig. 11-1) is provided as a means to prevent full closure of the damper blade. The clamp is easily attached to most

Page 4 - REPLACEMENT BURNER PARTS LIST

12INSTALLATION (cont.)8. Be sure gas to the fi replace is off. Attach the large adapter end of the fl ex connector to the gas-supply stub using a pipe

Page 5 - L-A2-208

13CONNECTING THE IGNITION PACK TO THE VALVEThe 01valve comes complete with the wiring harness connected to the switch box. You may wish to ensure it i

Page 6 - Valve, propane gas

14LOG PLACEMENTThe log set is purchased and packaged separately. Woodland Oak log set (WO) shown here. Styles and sizes will vary depending upon the l

Page 7 - HEAT SHIELD

15The log set is purchased and packaged separately. Charred Split Oak log set (CHS) shown here. Styles and sizes will vary depending upon the log set

Page 8

161. Tournez le cadran dans le sens des aiguilles d’une montre à OFF seulement quand l’arrêt complet est nécessaire.Fig. 16-11. S’ALLUMER - tournez l

Page 9

The Real-Fyre® burner system has a pilot that can be lit by hand using a match or lighter. When lighting the pilot, follow these instructions exactly.

Page 10 - IMPORTANT INFORMATION

18AVERTISSEMENT : Si vous ne suivez pas ces instructions exactement, une incendie ou une explosion peut résulter entraînant des dégats matériels, des

Page 11 - INSTALLATION

WARNINGIf you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life.LIGH

Page 12 - INSTALLATION (cont.)

REV 6 - 1305220905L-A2-2082ROBERT H. PETERSON CO. 14724 East Proctor Ave., City of Industry, CA 91746 , USAmanuel des manuel des propriétairespropriét

Page 13 - 01 VALVE MODELS ONLY

20INSTRUCTIONS D’ÉCLAIRAGE - SOUPAPE DE COMMANDE DE LA SÉRIE 01AVANT DE S’ALLUMER, sentez tous autour du secteur de brûleur à gaz pour le gaz. Soyez s

Page 14 - LOG PLACEMENT

211. STOP! Read the safety information above.2. Turn off any electrical appliance used with the burner system.3. Verify the switch (marked I = IGNIT

Page 15 - CHARRED LOG PLACEMENT

22AJUSTANT LE PILOTE1. La fl amme pilote devrait encercler le bout de générateur, et est préréglée à l’usine (Fig. 22-2). 2. Si l’ajustement est néce

Page 16 - Thermocouple

INTHTPTHTPINOUTADJUSTING THE PILOTa. The pilot fl ame should encircle the generator tip, and is preset at the factory (Fig. 23-2).b. If adjustment is

Page 17 - Pilot Assembly

24NOTES PAGEPlease use this page to record any information about your unit that you may want to have at hand.

Page 18

25PILOT BURNER ADJUSTMENTThe pilot burner is preset at the factory and should normally not require any adjustment. However, should adjustment be neces

Page 19

26POSSIBLE CAUSE SOLUTIONSBURNER SHUTTING DOWN DURING OPERATIONA. Insuffi cient or excessive gas pressureA1. Check gas pressure (Read G.- I. of IMPORT

Page 20 - AVERTISSEMENT

27POSSIBLE CAUSE SOLUTIONSSOOTINGA. On logs, in fi rebox, or room A. Check gas pressure (see Section 1, A1 of this table).B. Drafts in room B. Elimi

Page 21 - BEFORE LIGHTING

28PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASEThis warranty applies to the original purchaser and to single family residential use only

Page 22 - PORT PILOTE DE GAZ

REV 6 - 1305220905L-A2-2083TABLE OF CONTENTSTABLE OF CONTENTS4 REPLACEMENT BURNER PARTS LIST5 SAFETY CONTROL SYSTEM FOR MANUAL SERIES5 SAFETY CONTR

Page 23 - Fig. 23-2 Lighting the pilot

REV 6 - 1305220905L-A2-20841Note: Photos not to scale.8REPLACEMENT BURNER PARTS LIST2379For all valves, see detailed information on the following page

Page 24 - NOTES PAGE

REV 6 - 1305220905L-A2-2085SAFETY CONTROL SYSTEM FOR MANUAL SERIESSAFETY CONTROL SYSTEM FOR 17 SERIESPressure tapSAFETY CONTROL SYSTEM FOR 17 SERIES43

Page 25 - PILOT BURNER ADJUSTMENT

REV 6 - 1305220905L-A2-2086SAFETY CONTROL SYSTEM FOR 01 SERIESSAFETY CONTROL SYSTEM FOR 15 SERIES27531414235Item Description Part No. Qty.

Page 26

REV 6 - 1305220905L-A2-2087SAFETY CONTROL SYSTEM FOR 11 SERIES4123Item Description Part No. Qty.1. Heatshield HS-36 12 Valve assembly (nat

Page 27

8L'INFORMATION DE SÛRETÉ IMPORTANTE DE PRÉINSTALLATION ET DE CHEMINÉEA. Cet appareil est conçu comme appareil occupé. Les adultes doivent être p

Page 28 - WARRANTY

9IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATIONA. This appliance is designed as an attended appliance. Adults must be present when this